  • 7 - digit LCD-display
  • "°"- symbol for angle measurement
  • resolution up to 0.01 mm
  • 2 external inputs
  • 2 external outputs
  • simple installation (snap-in housing)
  • inch mode with fractional display
  • offset function: 3 respectively 15 (special version) 
  • switching between relative and absolute measuring
  • adjustable reference value
  • adjustable multiplication factor
  • possible interfaces: RS232 / RS422 / RS485 / 868 MHz
  • possible radio interface: 868 MHz
Technical Specifications

LCD-Display

7 decades (digit height 14 mm)

Measuring units

mm, m, inch oder "°"

Perspective

12 o'clock

Power supply

1.5 V or 3.0 V (+24 V on request)

Power consumption

< 1 mA at 1.5 V

Battery life

1 ... 3 years (depending on the battery-type)

Operating temperature

0 °C ... + 50 °C

Storage temperature

-20 °C ... + 80 °C

Humidity

max. 80 %, non-condensing

Velocity

max. 4 m/s

Housing

Norm panel housing, ABS plastic, black

Housing dimensions

W x H = 96 x 72 mm

Installation depth

30 mm (depending on version)

Panel cut out

W x H = 93 x 67 mm

Protection class front

IP 54 (when installed with sealing)
IP 43 (when installed without sealing)

Protection class back

IP 40


Magnetic sensor MS20.25

Pole length

2.5 mm

Senosr cable length

0.1 ... 2.0 m 

Senosr cable

Drag-chain suitable, 6-wires, twisted pairs and double shielded

Housing

Zinc die cast

Protection class

IP 67

Mounting position

User defined

Bending radius

min. 60 mm

Distance sensor/tape

max. 1.0 mm (without cover band)

Operating temperature

0 °C ... +50 °C

Storage temperature

-20 °C ... +80 °C

Influence of external magnetic fields

External magnetic fields > 1 mT, which directly impinge upon the sensor can affect the system accuracy


Magnetic tape MB 20-25-10-1-R

Coding

Incremental, single track

Pole length

2.5 mm

Operating temperature

0 °C ... +50 °C

Storage temperature

short-term: -10 °C...+60 °C, medium-term: 0 °C...+40 °C, long-term: +18 °C

Relative humidity

max. 95 %, non-condensing

Accuracy at 20 °C in mm

+/- (0.025 + 0.02 x L) L = measuring length in meter

Thermal expansion

ΔL[m] = L[m] x α[1/K] x Δ[K]
(L= tape length in meter, Δ = relative temperature change)

Linear expansion coefficient

α = 16 x 10-6 1/K

Bendign radius

min. 150 mm

Available lenths

32 m (up to 70 m on request)

Weight of the magnetic tape

ca. 62 g/m (incl. adhesive tape + protective tape)

Weight of cover band

ca. 19 g/m (incl. adhesive tape + protective tape)

Influence of external magnetic fields

External magnetic fields are not allowed to exceed 64 mT (640 Oe; 52 kA/m) at the magnetic tape surface, because it can destroy and damage the magnetic tape code. 

Protection class

IP 67

Mactrol.org @ 2010   B- 16/2, Meerut Road, Indl. Area,