- 7 - digit LCD-display
- "°"- symbol for angle measurement
- resolution up to 0.01 mm
- 2 external inputs
- 2 external outputs
- simple installation (snap-in housing)
- inch mode with fractional display
- offset function: 3 respectively 15 (special version)
- switching between relative and absolute measuring
- adjustable reference value
- adjustable multiplication factor
- possible interfaces: RS232 / RS422 / RS485 / 868 MHz
- possible radio interface: 868 MHz
|
 |
|
Technical Specifications |
LCD-Display | 7 decades (digit height 14 mm) | Measuring units | mm, m, inch oder "°" | Perspective | 12 o'clock | Power supply | 1.5 V or 3.0 V (+24 V on request) | Power consumption | < 1 mA at 1.5 V | Battery life | 1 ... 3 years (depending on the battery-type) | Operating temperature | 0 °C ... + 50 °C | Storage temperature | -20 °C ... + 80 °C | Humidity | max. 80 %, non-condensing | Velocity | max. 4 m/s | Housing | Norm panel housing, ABS plastic, black | Housing dimensions | W x H = 96 x 72 mm | Installation depth | 30 mm (depending on version) | Panel cut out | W x H = 93 x 67 mm | Protection class front | IP 54 (when installed with sealing) IP 43 (when installed without sealing) | Protection class back | IP 40 | Magnetic sensor MS20.25
| Pole length | 2.5 mm | Senosr cable length | 0.1 ... 2.0 m | Senosr cable | Drag-chain suitable, 6-wires, twisted pairs and double shielded | Housing | Zinc die cast | Protection class | IP 67 | Mounting position | User defined | Bending radius | min. 60 mm | Distance sensor/tape | max. 1.0 mm (without cover band) | Operating temperature | 0 °C ... +50 °C | Storage temperature | -20 °C ... +80 °C | Influence of external magnetic fields | External magnetic fields > 1 mT, which directly impinge upon the sensor can affect the system accuracy | Magnetic tape MB 20-25-10-1-R
| Coding | Incremental, single track | Pole length | 2.5 mm | Operating temperature | 0 °C ... +50 °C | Storage temperature | short-term: -10 °C...+60 °C, medium-term: 0 °C...+40 °C, long-term: +18 °C | Relative humidity | max. 95 %, non-condensing | Accuracy at 20 °C in mm | +/- (0.025 + 0.02 x L) L = measuring length in meter | Thermal expansion | ΔL[m] = L[m] x α[1/K] x Δ[K] (L= tape length in meter, Δ = relative temperature change) | Linear expansion coefficient | α = 16 x 10-6 1/K | Bendign radius | min. 150 mm | Available lenths | 32 m (up to 70 m on request) | Weight of the magnetic tape | ca. 62 g/m (incl. adhesive tape + protective tape) | Weight of cover band | ca. 19 g/m (incl. adhesive tape + protective tape) | Influence of external magnetic fields | External magnetic fields are not allowed to exceed 64 mT (640 Oe; 52 kA/m) at the magnetic tape surface, because it can destroy and damage the magnetic tape code. | Protection class | IP 67 |
|
|