Home Page About Us Products Serices Support Contact us
Measuring > Linear Encoders > MIX/FMIX
MIX: The incremental linear encoder for angular and linear movement
FMIX: Mechanically guided MIX with rail and carriage
 
Functions
The flexible magnetic tape also makes angle measurements possible (only MIX) and can be delivered lengths up to 30 Meters.
The resolution of MIX unit can be adjusted between 1 mm and 0.005 mm (by BCD-switch), but must be indicated at FMIX systems.
To reach the indicated/adjusted resolution, an evaluation of all 4 pulse-edges must be adjusted at the following circuit (e.g. With MIX units it is possible to integrate a reference sensor into the measuring head, which is putting out an index pulse when the reference mark has been passed. The reference mark (pole pair stripes) may be fixed at any position at the side of the magnetic MIX is available in four different versions:
MIX 1: Translator with a small external sensor
MIX3: Translator and sensor in one big case
MIX4:Translator and sensor in one big case with single time index pulse
MIX5:Translator and sensor in one big case with permanent index pulse
MIX5-SN033 with an additional input for enabling the reference procedure
The guided FMIX system is available in three different variants:
FMIX3: Without marker (index) pulse and end-switches
FMIX4: With integrated marker (index) pulse*
FMIX5: With integrated marker (index) pulse and end switches (opener relays)*
* The index pulse can be switched over single time or permanently, by an external input.
Features
The incremental measuring system MIX measures movements directly, that means there are no pitch or measuring errors due to mechanical play. The distance between magnetic sensor and magnetic tape may be up to 2.0 mm without impairing system accuracy.
 
Technical Specifications
Resolution: 1.0 / 0.5 / 0.1 / 0.05 / 0.01 / 0.005 mm
Repeat accuracy (+/-): +/- 1 Increment
Power supply: stabilized 10... 30 VDC or 5 VDC
Signal level: 10... 30 VDC or 5 VDC
Output frequency: 16 KHz (signal level 10... 30 VDC)
100 KHz (signal level 5 VDC)
Power consumption: max. 150 mA (supply 10... 30 VDC)
max. 200 mA (supply 5 VDC)
Output current: max. 20 mA per channel
Outputs: HTL/push-pull or 5 V/TTL
Max. distance tape / sensor: 2.0 mm
Duration of reference impulse: 250 µs
Operation speed for reference drive: max. 0.1 m/sec.
Operating temperature: 0...+ 50 °C
Sensor housing: MIX
die cast zinc, L x W x H = 25 x 10 x 15 mm (MIX sensor)
L x W x H = 72 x 24 x 48mm (MIX 1-5)
FMIX:
Sensor with guide carriage: L x W x H = 90 x 48 x 28 mm
Protection class: IP67 (sealed, MIX 1) or IP 54 (MIX 1-5)
FMIX: IP54 (standard), IP67 (Option V)
   
 
Mactrol.org @ 2010   B- 16/2, Meerut Road, Indl. Area,
Ghaziabad- 201 103