Features
The IndraDrive C series of converters integrate inverter and power supply in one
unit. The compact construction contains additional mains connection components,
making it particularly suitable for single-axis applications. |
|
|
Technical Data
|
Continous current |
[A] |
4,5 |
12 |
20,6 |
28 |
Maximum current |
[A] |
11,5 |
28,3 |
54 |
70,8 |
Motor nominal power typ. |
[kW] |
1,5 |
4 |
7,5 |
11 |
Mains voltage |
1 AC |
200...250 V
|
3 AC |
200...500 V
|
Tolerances |
[%] |
± 10 %
|
Frequency |
50...60 Hz
|
Frequency tolerances |
[Hz] |
± 2 Hz
|
Continous input mains current |
[A] |
6 |
13 |
20 |
30 |
Dependence of output on mains voltage |
ULN < 400 V |
1 % power reduction per 4 V
|
ULN > 400 V |
1 % power gain per 5 V
|
Mains contactor |
|
external
|
Continuous output with choke |
[kW] |
2,1 |
5,1 |
10 |
14 |
Max. output with choke |
[kW] |
5 |
10 |
16 |
19 |
Continuous output without choke |
[kW] |
2,1 |
5,1 |
7 |
9 |
Max. output without choke |
[kW] |
5 |
8 |
12 |
14 |
Switching frequency/max. output frequency |
4 kHz |
0...400 Hz
|
8 kHz |
0...800 Hz
|
12 kHz |
0...1200 Hz
|
16 kHz |
0...1600 Hz
|
Output voltage |
[V] |
3 x AC 0...main voltage V
|
DC bus capacity |
[mF] |
0,135 |
0,27 |
0,54 |
0,675 |
DC bus voltage |
[V] DC |
Main voltage x 1,41
|
Converter/inverter combination |
|
●
|
Brake resistor |
Internal |
internal/external |
Brake chopper |
Internal
|
Braking Energy Consumption |
[kWs] |
1 |
5 |
9 |
13 |
Continuous braking power |
[kW] |
0,05 |
0,15 |
0,35 |
0,5 |
Maximum braking power |
[kW] |
4 |
10 |
18 |
25 |
Control Voltage |
external |
24V ± 20%
|
Internal |
24V ± 10%
|
Power consumption without control unit and motor brake |
[W] |
12 |
14 |
23 |
Category Total |
IP20 (IEC529)
|
Degree of contamination |
2 (EN50178)
|
EMC |
EN61800-3
|
Cooling system |
forced ventilated
|
Certification |
EN61800-5-1
UL 508 C
|
Canadian National Standard(s) C22.2 No. 14-05
|
Weight |
[kg] |
2,9 |
3,8 |
6,7 |
6,8 |
Ambient temp. operation |
[°C] |
0 ... 40 °C
|
Derating [°C] |
0 ... 55 °C
|
Ambient temp. storage |
[°C] |
-25...55 °C
|
Relative humidity operation |
[%] |
5...95 %
|
Relative humidity storage |
[%] |
5...95 %
|
Installation height |
[m] |
1000
|
[m] Derating |
4000
|
|