Home Page About Us Products Serices Support Contact us
HCS 02 

Features

The IndraDrive C series of converters integrate inverter and power supply in one unit. The compact construction contains additional mains connection components, making it particularly suitable for single-axis applications.
Technical Data
  HCS02.1E-W0012 HCS02.1E-W0028 HCS02.1E-W0054 HCS02.1E-W0070
Power
Continous current [A] 4,5 12 20,6 28
Maximum current [A] 11,5 28,3 54 70,8
Motor nominal power typ. [kW] 1,5 4 7,5 11
Mains voltage 1 AC
200...250 V
3 AC
200...500 V
Tolerances [%]
± 10 %
Frequency
50...60 Hz
Frequency tolerances [Hz]
± 2 Hz
Continous input mains current [A] 6 13 20 30
Dependence of output on mains voltage ULN < 400 V
1 % power reduction per 4 V
ULN > 400 V
1 % power gain per 5 V
Mains contactor  
external
DC bus
Continuous output with choke [kW] 2,1 5,1 10 14
Max. output with choke [kW] 5 10 16 19
Continuous output without choke [kW] 2,1 5,1 7 9
Max. output without choke [kW] 5 8 12 14
Switching frequency/max. output frequency 4 kHz
0...400 Hz
8 kHz
0...800 Hz
12 kHz
0...1200 Hz
16 kHz
0...1600 Hz
Output voltage [V]
3 x AC 0...main voltage V
DC bus capacity [mF] 0,135 0,27 0,54 0,675
DC bus voltage [V] DC
Main voltage x 1,41
Converter/inverter combination  
Brake chopper / resistor
Brake resistor Internal internal/external
Brake chopper
Internal
Braking Energy Consumption [kWs] 1 5 9 13
Continuous braking power [kW] 0,05 0,15 0,35 0,5
Maximum braking power [kW] 4 10 18 25
Control Voltage
Control Voltage external
24V ± 20%
Internal
24V ± 10%
Power consumption without control unit and motor brake [W] 12 14 23
Protection
Category Total
IP20 (IEC529)
Degree of contamination
2 (EN50178)
EMC
EN61800-3
Cooling system
forced ventilated
Standards
Certification
EN61800-5-1
UL 508 C
Canadian National Standard(s) C22.2 No. 14-05
Weight
Weight [kg] 2,9 3,8 6,7 6,8
Ambient conditions
Ambient temp. operation [°C]
0 ... 40 °C
Derating [°C]
0 ... 55 °C
Ambient temp. storage [°C]
-25...55 °C
Relative humidity operation [%]
 5...95 %
Relative humidity storage [%]
 5...95 %
Installation height [m]
1000
[m] Derating
4000
Dimensions
  HCS02.1E-W0012 HCS02.1E-W0028 HCS02.1E-W0054 HCS02.1E-W0070
Dimensions
Dimensions (H x W x D) 290 x 65 x 206 mm 352 x 65 x 206 mm 352 x 105 x 206 mm 352 x 105 x 206 mm
Height H [mm] 290 352 352 352
Width W [mm] 65 65 105 105
Depth D [mm] 206 206 206 206
Mactrol.org @ 2010   B- 16/2, Meerut Road, Indl. Area,