Features
The IndraDrive C series of converters integrate inverter and power supply in one unit. The compact construction contains additional mains connection components, making it particularly suitable for single-axis applications.
|
|
|
Technical Data
|
Continous current |
[A] |
45 |
73 |
95 |
145 |
Maximum current |
[A] |
70 |
100 |
150 |
210 |
Motor nominal power typ. |
[kW] |
22 |
37 |
45 |
75 |
Mains voltage |
3 AC |
400...500 V
|
Tolerances |
[%] |
+10 -15 %
|
Frequency |
50...60 Hz
|
Frequency tolerances |
[Hz] |
± 2 Hz
|
Continous input mains current |
[A] |
50 |
80 |
106 |
146 |
Dependence of output on mains voltage |
ULN < 400 V |
1 % power reduction per 4 V
|
ULN > 400 V |
1 % power gain per 5 V
|
Mains contactor |
|
external
|
Continuous output with choke |
[kW] |
25 |
43 |
56 |
85 |
Max. output with choke |
[kW] |
40 |
59 |
89 |
124 |
Continuous output without choke |
[kW] |
13 |
24 |
34 |
47 |
Max. output without choke |
[kW] |
20 |
33 |
54 |
68 |
Switching frequency/max. output frequency |
4 kHz |
0...400 Hz
|
8 kHz |
0...800 Hz
|
12 kHz |
0...1200 Hz
|
16 kHz |
0...1600 Hz
|
Output voltage |
[V] |
3 x AC 0...480 V
|
DC bus capacity |
[mF] |
0,94 |
1,44 |
1,88 |
4,7 |
DC bus voltage |
[V] DC |
Main voltage x 1,41
|
Converter/inverter combination |
|
?
|
Brake resistor |
external
|
Brake chopper |
Internal
|
Braking Energy Consumption |
[kWs] |
42 |
63 |
97 |
137 |
Continuous braking power |
[kW] |
13,2 |
18,9 |
25,2 |
42,6 |
Control Voltage |
external |
24V ± 20%
|
Internal |
24V
|
Power consumption without control unit and motor brake |
[W] |
22,5 |
25 |
30 |
Category Total |
IP20 (IEC529)
|
Degree of contamination |
2 (EN50178)
|
EMC |
EN61800-3
|
Cooling system |
forced ventilated
|
Certification |
EN61800-5-1
UL 508 C
|
Canadian National Standard(s) C22.2 No. 14-05
|
Weight |
[kg] |
13 |
20 |
20 |
38 |
Ambient temp. operation |
[°C] |
0 ... 40 °C
|
Derating [°C] |
0 ... 55 °C
|
Ambient temp. storage |
[°C] |
-25...55 °C
|
Relative humidity operation |
[%] |
5...95 %
|
Relative humidity storage |
[%] |
5...95 %
|
Installation height |
[m] |
1000
|
[m] Derating |
4000
|
All data for nominal rating at 3 AC 400 V mains voltage and 4 kHz switching frequency |
|